Dry dial, magnetic transmission.
Sizes: DN50 to 300mm (2” – 12”), cold water(30°C)
Tangential meter for irrigation use, make DIN and ANSI standard.
Pre-equipped for impulse emitter device.
Accuracy: Class A, suitable for dirty water
MAIN TECHNICAL DATA
Size | Class | Max | Norminal Flow | Transitional Flow | Min Flow | Min Reading | Max Reading |
m3/h | m3 | ||||||
mm | |||||||
50 | A | 30 | 15 | 4.5 | 1.2 | 0.01 | 9,999,999 |
65 | A | 50 | 25 | 7.5 | 2 | 0.01 | 9,999,999 |
80 | A | 80 | 40 | 12 | 3.2 | 0.01 | 99,999,999 |
100 | A | 120 | 60 | 18 | 4.8 | 0.01 | 99,999,999 |
125 | A | 200 | 100 | 30 | 8 | 0.01 | 99,999,999 |
150 | A | 300 | 150 | 45 | 12 | 0.01 | 99,999,999 |
200 | A | 500 | 250 | 75 | 20 | 0.01 | 99,999,999 |
250 | A | 800 | 400 | 120 | 32 | 0.1 | 99,999,999 |
300 | A | 1200 | 600 | 180 | 48 | 0.1 | 99,999,999 |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) totransitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) tooverload flow rate (qs)
DIMENSIONS AND WEIGHT
Size | Length | Width | Height | Connecting flange | Weight | |||
Outer diameter | Bolt cierle D2 | Connecting bolt | Kg | |||||
mm | ||||||||
50 | 200 | 165 | 267 | 256 | 165 | 125 | 4-M16 | 10.4 |
65 | 200 | 185 | 279 | 268 | 185 | 145 | 4-M16 | 14 |
80 | 225 | 200 | 295 | 284 | 200 | 160 | 8-M16 | 16 |
100 | 250 | 220 | 306 | 295 | 220 | 180 | 8-M16 | 19 |
125 | 250 | 250 | 321 | 310 | 250 | 210 | 8-M16 | 25.3 |
150 | 300 | 285 | 351 | 340 | 285 | 240 | 8-M16 | 28.1 |
200 | 350 | 340 | 393 | 385 | 340 | 295 | 8-M16 | 48 |
250 | 400 | 395 | 441 | 435 | 395 | 350 | 12-M20 | 76 |
300 | 450 | 445 | 491 | 485 | 445 | 400 | 12-M20 | 85 |
WORKING CONDITION
Water temperature:≤30℃ for cold water meter
Working pressure:≤1.6Mpa