Multi jet, Dry-dial, wet dial and liquid sealed for option
Material body: Cast gray iron or ductile iron for option
Size 50mm, ( 2”), Available for cold water (30°C), hot(90°C)
Measuring accuracy conform to ISO 4064 class B Standard
Universal use. Easy for interchange & maintenance
MAIN TECHNICAL DATA
Meter size Dia DN (mm) | Class | qs Overload Flow | qs Nominal Flow | qs Transitional Flow | Qmin Min Flow | Min Reading Lectura | Max Reading Lectura |
m3/h | 1/h | m3 | |||||
50 | A | 30 | 15 | 1500 | 600 | 0.001 | 99999 |
B | 1200 | 300 |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
DIMENSIONS AND WEIGHT
Meter size Dia DN (mm) | Length | Width | Height | Connecting Thread D | Weight Kg |
mm | |||||
50 | 300 | 125 | 155 | G2 1/2 B | 15.0 |
280 | 165 | 175 | FLANGE CONNECTING CONFORM TO GB4216.4 D=165 D1=125 | 17.5 |
WORKING CONDITION
Water temperature:≤50℃ for cold water meter
Water temperature:≤90℃ for hot water meter
Working pressure:≤1.0Mpa